1234567891011121314151617181920212223242526272829303132333435363738394041 |
- From 7eb68a2a0519a77b93184c695d4d293c92dc2286 Mon Sep 17 00:00:00 2001
- From: =?UTF-8?q?Rafa=C5=82=20Mi=C5=82ecki?= <zajec5@gmail.com>
- Date: Wed, 11 Feb 2015 16:40:58 +0100
- Subject: [PATCH] ARM: BCM5301X: Ignore another (BCM4709 specific) fault code
- MIME-Version: 1.0
- Content-Type: text/plain; charset=UTF-8
- Content-Transfer-Encoding: 8bit
- Broadcom ARM devices seem to generate some fault once per boot. We
- already have an ignoring handler for BCM4707/BCM4708, but BCM4709
- generates different code.
- Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
- Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
- ---
- arch/arm/mach-bcm/bcm_5301x.c | 9 +++++----
- 1 file changed, 5 insertions(+), 4 deletions(-)
- --- a/arch/arm/mach-bcm/bcm_5301x.c
- +++ b/arch/arm/mach-bcm/bcm_5301x.c
- @@ -18,15 +18,16 @@ static bool first_fault = true;
- static int bcm5301x_abort_handler(unsigned long addr, unsigned int fsr,
- struct pt_regs *regs)
- {
- - if (fsr == 0x1c06 && first_fault) {
- + if ((fsr == 0x1406 || fsr == 0x1c06) && first_fault) {
- first_fault = false;
-
- /*
- - * These faults with code 0x1c06 happens for no good reason,
- - * possibly left over from the CFE boot loader.
- + * These faults with codes 0x1406 (BCM4709) or 0x1c06 happens
- + * for no good reason, possibly left over from the CFE boot
- + * loader.
- */
- pr_warn("External imprecise Data abort at addr=%#lx, fsr=%#x ignored.\n",
- - addr, fsr);
- + addr, fsr);
-
- /* Returning non-zero causes fault display and panic */
- return 0;
|